CSpace  > 中国科学院计算技术研究所期刊论文  > 英文
AutoHR: A Strong End-to-End Baseline for Remote Heart Rate Measurement With Neural Searching
Yu, Zitong1; Li, Xiaobai1; Niu, Xuesong2,3; Shi, Jingang4,5; Zhao, Guoying6
2020
发表期刊IEEE SIGNAL PROCESSING LETTERS
ISSN1070-9908
卷号27页码:1245-1249
摘要Remote photoplethysmography (rPPG), which aims at measuring heart activities without any contact, has great potential in many applications (e.g., remote healthcare). Existing end-to-end rPPG and heart rate (HR) measurement methods from facial videos are vulnerable to the less-constrained scenarios (e.g., with head movement and bad illumination). In this letter, we explore the reason why existing end-to-end networks perform poorly in challenging conditions and establish a strong end-to-end baseline (AutoHR) for remote HR measurement with neural architecture search (NAS). The proposed method includes three parts: 1) a powerful searched backbone with novel Temporal Difference Convolution (TDC), intending to capture intrinsic rPPG-aware clues between frames; 2) a hybrid loss function considering constraints from both time and frequency domains; and 3) spatio-temporal data augmentation strategies for better representation learning. Comprehensive experiments are performed on three benchmark datasets, and we achieved superior performance on both intra- and cross-dataset testings.
关键词RPPG heart rate neural architecture search
DOI10.1109/LSP.2020.3007086
收录类别SCI
语种英语
资助项目National Natural Science Foundation of China[61772419] ; Academy of Finland[316765] ; ICT 2023 project[328115] ; Infotech Oulu
WOS研究方向Engineering
WOS类目Engineering, Electrical & Electronic
WOS记录号WOS:000554896000003
出版者IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
引用统计
被引频次:74[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://119.78.100.204/handle/2XEOYT63/15862
专题中国科学院计算技术研究所期刊论文_英文
通讯作者Zhao, Guoying
作者单位1.Univ Oulu, Ctr Machine Vis & Signal Anal CMVS, Oulu 90014, Finland
2.Chinese Acad Sci, Inst Comp Technol, Key Lab Intelligent Informat Proc, Beijing 100190, Peoples R China
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
4.Xi An Jiao Tong Univ, Sch Software Engn, Xian 710049, Shaanxi, Peoples R China
5.Univ Oulu, CMVS, Oulu 90014, Finland
6.Northwest Univ, Sch Informat & Technol, Xian 710069, Shaanxi, Peoples R China
推荐引用方式
GB/T 7714
Yu, Zitong,Li, Xiaobai,Niu, Xuesong,et al. AutoHR: A Strong End-to-End Baseline for Remote Heart Rate Measurement With Neural Searching[J]. IEEE SIGNAL PROCESSING LETTERS,2020,27:1245-1249.
APA Yu, Zitong,Li, Xiaobai,Niu, Xuesong,Shi, Jingang,&Zhao, Guoying.(2020).AutoHR: A Strong End-to-End Baseline for Remote Heart Rate Measurement With Neural Searching.IEEE SIGNAL PROCESSING LETTERS,27,1245-1249.
MLA Yu, Zitong,et al."AutoHR: A Strong End-to-End Baseline for Remote Heart Rate Measurement With Neural Searching".IEEE SIGNAL PROCESSING LETTERS 27(2020):1245-1249.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yu, Zitong]的文章
[Li, Xiaobai]的文章
[Niu, Xuesong]的文章
百度学术
百度学术中相似的文章
[Yu, Zitong]的文章
[Li, Xiaobai]的文章
[Niu, Xuesong]的文章
必应学术
必应学术中相似的文章
[Yu, Zitong]的文章
[Li, Xiaobai]的文章
[Niu, Xuesong]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。