Institute of Computing Technology, Chinese Academy IR
A New 6D Magnetic Localization Technique for Wireless Capsule Endoscope Based on a Rectangle Magnet | |
Yang Wan'an1,2,4,5; Hu Chao2; Meng, Max Q. H.2,3; Dai Houde2; Chen Dongmei2 | |
2010-04-01 | |
发表期刊 | CHINESE JOURNAL OF ELECTRONICS |
ISSN | 1022-4653 |
卷号 | 19期号:2页码:360-364 |
摘要 | To build a wireless active endoscope with external guidance for controllable and interactive GI track diagnosis, a real time system for 3D localization and 3D orientation is necessary. An approach is to enclose a small rectangle permanent magnet in the capsule. The magnetic field, produced by the rectangle magnet around the body, can be detected by magnetic sensors outside the patient's body. With these sensor data, the 3D localization and 3D orientation parameters can be computed by the nonlinear optimization algorithm based on the mathematic model of the rectangular magnet's magnetic field. Simulation experiments show that the proposed algorithm works effectively, and has good accuracy and time efficiency when the initial guess of the parameters are within some predetermined ranges. |
关键词 | Wireless active endoscope 6D localization and orientation Rectangle magnet Nonlinear minimization |
收录类别 | SCI |
语种 | 英语 |
资助项目 | Chinese National High Technology Research[2007AA01Z308] ; Hong Kong Government[CUHK4213/04E] |
WOS研究方向 | Engineering |
WOS类目 | Engineering, Electrical & Electronic |
WOS记录号 | WOS:000277070900035 |
出版者 | TECHNOLOGY EXCHANGE LIMITED HONG KONG |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://119.78.100.204/handle/2XEOYT63/11991 |
专题 | 中国科学院计算技术研究所期刊论文_英文 |
通讯作者 | Yang Wan'an |
作者单位 | 1.Chinese Acad Sci, Inst Comp Technol, Beijing 100190, Peoples R China 2.Chinese Univ Hong Kong, Shenzhen Inst Adv Technol, Chinese Acad Sci, Shenzhen Inst Adv Integrat Technol, Shenzhen 518067, Peoples R China 3.Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China 4.Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China 5.Yibin Univ, Dept Comp & Informat Technol, Yibin 644000, Peoples R China |
推荐引用方式 GB/T 7714 | Yang Wan'an,Hu Chao,Meng, Max Q. H.,et al. A New 6D Magnetic Localization Technique for Wireless Capsule Endoscope Based on a Rectangle Magnet[J]. CHINESE JOURNAL OF ELECTRONICS,2010,19(2):360-364. |
APA | Yang Wan'an,Hu Chao,Meng, Max Q. H.,Dai Houde,&Chen Dongmei.(2010).A New 6D Magnetic Localization Technique for Wireless Capsule Endoscope Based on a Rectangle Magnet.CHINESE JOURNAL OF ELECTRONICS,19(2),360-364. |
MLA | Yang Wan'an,et al."A New 6D Magnetic Localization Technique for Wireless Capsule Endoscope Based on a Rectangle Magnet".CHINESE JOURNAL OF ELECTRONICS 19.2(2010):360-364. |
条目包含的文件 | 条目无相关文件。 |